Microcomputer Systems MSI-P602 Manual de usuario

Busca en linea o descarga Manual de usuario para Módulos Receptores Gps Microcomputer Systems MSI-P602. Microcomputer Systems MSI-P602 User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
PC/104 Embedded
Industrial Analog I/O Series
Microcomputer Systems, Inc.
1814 Ryder Drive ¨ Baton Rouge, LA 70808
Ph (225) 769-2154 ¨ Fax (225) 769-2155
http://www.microcomputersystems.com
MSI-P602 Trimble Lassen
iQ GPS & Digital I/O Card
Revision 2
User Manual
Vista de pagina 0
1 2 3 4 5 6 ... 20 21

Indice de contenidos

Pagina 1 - User Manual

PC/104 EmbeddedIndustrial Analog I/O SeriesMicrocomputer Systems, Inc.1814 Ryder Drive ¨ Baton Rouge, LA 70808Ph (225) 769-2154 ¨ Fax (225) 769-2155Em

Pagina 2 - APPENDIX

D. Digital I/O Registers and Connections.Four digital TTL inputs and four digital TTL outputs areprovided by the modem status and modem control regist

Pagina 3 - BLANK PAGE

Page 11 MSI-P602 User ManualE. 3.0V BatteryA socketed 3.0V battery is included for enhancing GPS dataacquisition time by maintaining memory du

Pagina 4 - BLOCK DIAGRAM

III. GPS SOFTWARE COMMANDSA. Trimble Standard Interface Protocol (TSIP)The Trimble Standard Interface Protocol (TSIP) provides thesystem designer wi

Pagina 5

Page 13 MSI-P602 User ManualB. Trimble ASCII Interface Protocol (TAIP)CTrimble ASCII Interface Protocol (TAIP) is a Trimble-specifieddigital c

Pagina 6 - II. HARDWARE DESCRIPTION

Page 14 MSI-P602 User ManualC. NMEA 0183EAppendix E, beginning on page 209 of theLassen iQ_Reference Manual_Rev b.pdf(included on the CDROM of

Pagina 7

Page 15 MSI-P602 User ManualIV. SAMPLE BASIC LANGUAGE TEST PROGRAMThe BASIC language program below illustrates software sequencesfor TSIP and

Pagina 8

Page 16 MSI-P602 User ManualGOSUB setDOutputGOTO beginCASE “4” ‘set /OUT1_BUFFERED = 1z = 1GOSUB setDOutputGOTO beginCASE “5” ‘display digi

Pagina 9

Page 17 MSI-P602 User Manualpchar = &H10: GOSUB sendpchar ‘send <DLE>pchar = &H3: GOSUB sendpchar ‘send <ETX>GOTO beginCA

Pagina 10

Page 18 MSI-P602 User Manualgetsecondarychar:IF (INP(secondary + 5) AND 1) = 1 THENz = INP(secondary)IF NMEA = 1 THENPRINT CHR$(z);ELSEPRINT C

Pagina 11

V. SPECIFICATIONSPC/104 16-bit, stackthroughGPS ReceiverFrequency L1, 1575.42 MHzC/A CodeChannels 12, continuous trackingGPS AccuracyHorizontal < 5

Pagina 12 - III. GPS SOFTWARE COMMANDS

CONTENTSI. INTRODUCTION 4II.HARDWARE DESCRIPTION 6A. Card Configuration 6B. Card Addressing 7C. Interrupt Connections 8D. Digital I/O Registers a

Pagina 13

Page 26 MSI-P602 User ManualGPS AntennaActive with 5m (16.5 ft) cableModel Compact Magnetic MountDigital I/O Port4 Input TTL level (Inverted)4

Pagina 14

APPENDIXSchematic Diagrams of the MSI-P6021) P602-1.sch - Schematic sheet 1 of 2.See p602r2-1.pdf2) P602-2.sch - Schematic sheet 2 of 2.See p602r2-2.p

Pagina 15

BLANK PAGE

Pagina 16

Figure 1. Block Diagram of the MSI-P602.I. INTRODUCTIONThe MSI-P602 is a low cost, high performance global positioningsystem which uses the Trimble L

Pagina 17

Page 5 MSI-P602 User ManualNMEA output at a default BAUD rate of 4800. Softwareselectable NMEA protocols using the secondary serial port areGG

Pagina 18

II. HARDWARE DESCRIPTIONA. Card ConfigurationThe MSI-P602 card is a CMOS design using through-hole andsurface-mounted devices. The card configurat

Pagina 19 - V. SPECIFICATIONS

B. Card AddressingThe card address is set by installing appropriate jumper pairson JP2, pins 1 thru 13, as shown in Fig. 3. An installed jumperfor a

Pagina 20

do not install JP2-13 so that COM3 and COM4 are selected forthe primary and secondary serial ports. If your CPU containsCOM1 thru COM4 ports and you a

Pagina 21

4) JP1-12 is connected to the interrupt request signal of thesecondary UART (TAIP/NMEA protocol). This can jumpered toa desired interrupt, IRQ4 thru I

Comentarios a estos manuales